I/O Controllers

  • SAE J1939 CAN engine message reception and Es-Key network controller.
  • Digital circuit breakers on all positive outputs.
  • Output ‘open load’ detection.
  • Diagnostic LED indicators.
  • Optional modem available upon request.
  • Environmentally sealed - IP67.
  • Multi-voltage.
  • Voltage: 9-32V
  • Body: Polycarbonate
  • Current Draw: 100mA @ 13.8V
    125mA @ 27.6V
  • Inputs: 6 Polarity selectable
  • Outputs: 8 Polarity selectable
  • IP Rating: IP67
  • CAN: SAE J1939
  • Operating Temp: -40­­°C to 85°C
  • Introduces switched inputs into the
  • Es-Key network.
  • Up to 18 inputs and 16 outputs.
  • Environmentally sealed - IP67.
  • Multi-voltage.
  • Voltage: 9-32V
  • Current Draw: 103mA @ 13.8V Maximum
  • Output: 0.25A to 10.5A Maximum
  • Outputs: 3, 5, 12, 16 & 24 Models
  • CAN: SAE J1939
  • Housing Material: Polycarbonate
  • IP Rating: IP67
  • Approvals: SAE J1113
    ISO 11452
  • Operating Temp: -40°C to 85°C
  • Supplies power to system loads, and introduces digital/analogue inputs into the Es-Key network.
  • Selectable polarity for digital inputs models.
  • Up to 12 outputs from a single module.
  • Environmentally sealed - IP67.
  • Multi-voltage.
  • Voltage: 9-32V
  • CAN: SAE J1939
  • Inputs: 0-4
  • Outputs: 4-8
    8-12
  • Current Rating: 7.5A Max.
  • Body: PC
  • IP Rating: IP67
  • Approvals: SAE J1113
    MIL-STD-810F
    ISO4892
  • Operating Temp: -40°C to 85°C

The Supernode II consolidates the functions of several Es-Key modules - USM, Data Logger, Seatbelt, Vehicle Data Recorder (VDR), Climate Control, Digital Input/Output Module & Power Distribution Module. This reduces node count and simplifies addressing. Making it well suited for applications where a centralised node location is required.

  • SAE J1939 CAN engine message reception and Es-Key network controller.
  • Digital circuit breakers on all positive outputs.
  • Output ‘open load’ detection.
  • Diagnostic LED indicators.
  • Optional modem available upon request.
  • Environmentally sealed - IP67.
  • Multi-voltage.
  • Voltage: 9-32V
  • Body: Die-cast
  • Current Draw: 500mA @ 13.8V
    350mA @ 27.6V
  • Inputs: 24 Polarity selectable
  • Outputs: 18 Positive
    @ 13A
    6 Negative
    @ 2A
  • IP Rating: IP67
  • CAN: SAE J1939
  • Operating Temp: -40°C to 85°C
  • Note: Optional integrated modem available

Introduces switched inputs into the
Es-Key network.

Can accept multiple input signal types.

Environmentally sealed – IP67.

Multi-voltage.

Made in North America.

  • Voltage: 9-32V
  • Input Signal: 2 Internal
    2 External
  • Inputs: 1 Digital
  • Operating Temp: -40°C to 85°C
  • IP Rating: IP67
  • Outputs: 1 Digital
  • Supplies power to system loads, and introduces digital/analogue inputs into the Es-Key network.
  • Selectable polarity for digital inputs models.
  • 21 outputs from a single module.
  • LED display with 2 buttons for diagnostic, indication and configuration purposes.
  • Environmentally sealed - IP67.
  • Multi-voltage.
  • Voltage: 9-32V
  • CAN: SAE J1939
  • Inputs: 10
  • Outputs: 21
  • Current Rating: 13A Max.
  • Body: Die-cast
  • IP Rating: IP67
  • Approvals: SAE J1113
    MIL-STD-810F
    ISO4892
  • Operating Temp: -40°C to 85°C
  • Introduces switched inputs into the Es-Key network.
  • Up to 4 inputs and 5 outputs.
  • H-Bridge functionality.
  • Environmentally sealed - IP67.
  • Multi-voltage.
  • Housing Material: ABS - Epoxy Filled
  • CAN: SAE J1939
  • Output: 500mA x 3
    6A x 2 (H Bridge functionality)
  • Approvals: SAE J1113
    ISO 11452
  • IP Rating: IP67
  • Operating Temp: -40°C to 85°C
  • Current Draw: 30mA @ 13.8V
  • Voltage: 9-32V
  • SAE J1939 CAN engine message reception and Es-Key network controller.
  • Digital circuit breakers on all positive outputs.
  • Output ‘open load’ detection.
  • Diagnostic LED indicators.
  • Selectable polarity for digital inputs models.
  • Environmentally sealed – IP67.
  • Multi-voltage.
  • Made in North America.
  • Voltage: 9-32V
  • Body: Die-cast
    Polycarbonate
  • Current Draw: 50mA @ 13.8V
    60mA @ 27.6V
  • Inputs: 8 Digital
  • Outputs: 16
  • Output Current: 13A Maximum
  • IP Rating: IP67
  • CAN: SAE J1939
  • Operating Temp: -40­­°C to 85°C
  • SAE J1939 CAN engine message reception and Es-Key network controller.
  • Digital circuit breakers on all positive outputs.
  • Output ‘open load’ detection.
  • Diagnostic LED indicators.
  • Selectable polarity for digital inputs models.
  • Environmentally sealed – IP67.
  • Multi-voltage.
  • Made in North America.
  • Voltage: 9-32V
  • Body: Die-cast
    Polycarbonate
  • Current Draw: 69mA @ 13.8V
    63mA @ 27.6V
  • Inputs: 4 Analogue
    16 Digital
  • Outputs: 32
  • Output Current: Positive 13A
    4A Negative
  • IP Rating: IP67
  • CAN: SAE J1939
  • Operating Temp: -40­­°C to 85°C